Skip to main content
. 2022 Apr 15;30(2):e241045. doi: 10.1590/1413-785220223002241045

Table 2. Reliability analysis of the Lequesne and FABREX tests for the diagnosis of middle gluteus tendinopathy. Accuracy measures and coefficient Kappa.

Test/Result Tendinopathy gluteus medius Sens. (%) Spec. (%) PPV+ (%) NPV- (%) Accuracy (%) Kappa
present absent value p-value
LEQUESNE pos 11 9 78.6 75 55 90 76 0.47 0.0005
neg 3 27
Proposed PHASE 3 pos 12 11 85.7 69.4 52.2 92.6 74 0.46 0.0004
neg 2 25

Sens: sensitivity; Spec: specificity; PPV+: positive predictive value; NPV−: negative predictive value; Accuracy: percentage of positive and negative concordances.