Table 3. Reliability analysis of the Lequesne and FABREX tests for the diagnosis of middle gluteus tendinopathy. Accuracy measures and coefficient Kappa.

Test/Result Tendinopathy gluteus minimus Sens. (%) Spec. (%) PPV+ (%) NPV- (%) Accuracy (%) Kappa
present absent value p-value
LEQUESNE pos 17 3 65.4 87.5 85 70 76 0.52 0.0001
neg 9 21
Proposed PHASE 3 pos 21 2 80.8 91.7 91.3 81.5 86.0 0.72 < 0.0001
neg 5 22