Skip to main content
. 2022 Jun 17;842:156710. doi: 10.1016/j.scitotenv.2022.156710

Table 4.

Kinetic parameters of Ea, ƒ (α), and A for the MB, MF, and IT pyrolysis.

Samples β (°C/min) Ea (kJ/mol) f (a) FE A R2
MB 10 169.92 1.3(1 − α)[−ln(1 − α)]1/1.3 y = 1.2731x + 0.0057 1.2731 × 1012 0.9998
20 y = 1.4865x − 0.0158 1.4865 × 1012 0.9998
40 y = 1.5419x − 0.0989 1.5419 × 1012 0.9987
MF 10 231.56 1.4(1 − α)[−ln(1 − α)]1/1.4 y = 1.4616x − 0.0044 1.4616 × 1016 0.9986
20 y = 1.4754x − 0.0246 1.4754 × 1016 0.9993
40 y = 1.5179x − 0.0217 1.5179 × 1016 0.9977
IT stage I 10 102.51 (1 − α)1.2 y = 1.2067x + 0.0116 1.2067 × 109 0.9973
20 y = 1.4354x − 0.0153 1.4354 × 109 0.9997
40 y = 1.4692x − 0.0722 1.4692 × 109 0.9999
IT stage II 10 204.79 (1 − α)1.6 y = 1.6960x − 0.0455 1.6960 × 1014 0.9999
20 y = 1.8877x + 0.0237 1.8877 × 1014 0.9992
40 y = 1.5081x + 0.0528 1.5081 × 1014 0.9988