Skip to main content
. 2022 Jun 21;12:10458. doi: 10.1038/s41598-022-13508-3

Table 1.

Comparative performance of BRCA1/2 models across cross-validation and non-redundant blind test sets.

Model MCC Sensitivity Specificity F1 score Precision Accuracy
BRCA1-specific models
BRCA1 CV 0.96 93% 98% 0.96 0.96 0.96
test 0.89 92% 82% 0.86 0.87 0.86
BRCA1-combined CV 0.96 94% 98% 0.97 0.97 0.97
test 0.89 100% 91% 0.94 0.95 0.94
BRCA1-ENIGMA CV 0.96 99% 99% 0.99 0.99 0.99
test 0.82 92% 90% 0.93 0.94 0.92
BRCA2-specific models
BRCA2 CV 0.98 96% 98% 0.98 0.98 0.98
test 0.89 60% 100% 0.92 0.93 0.92
BRCA2-combined CV 0.89 82% 93% 0.91 0.91 0.91
test 0.83 86% 100% 0.97 0.98 0.97
BRCA2-ENIGMA CV 0.95 99% 99% 0.99 0.99 0.99
test 1.00 100% 100% 1.00 1.00 1.00
General model
BRCA1/2 general model CV 0.91 96% 98% 0.96 0.96 0.96
test 0.76 93% 100% 0.93 0.93 0.92