2 × 2 χ 2 Test Comparing the Number of Samples with a Positive Neutralizing Antibody Response to the Different SARS-CoV-2 Variants Between the Healthcare Worker Controls and Monoclonal Gammopathy Patient Group vs the Solid Organ Transplant Groupa

SARS-CoV-2 Strain Health Care Worker Controls and Monoclonal Gammopathy Patients (n = 32) Solid Organ Transplant Patients (n = 10) P Value
Original variant D614G 32 (100) 9 (90) .0736
Alpha variant B.1.1.7 32 (100) 8 (80) .0104
Beta variant B.1.351 31 (96.9) 7 (70) .0125
Gamma variant B.1.1.28 31 (96.9) 7 (70) .0125
Delta variant B.1.617 32 (100) 5 (50) <.0001

aData are given as No. (%).