Skip to main content
. 2022 Jun 21;22:415. doi: 10.1186/s12888-022-04038-3

Table 2.

The diagnostic efficacy calculation results of WeDA system and SNAP-IV

Specificity (%) Sensitivity (%) Youden index PLR NLR Diagnostic odds ratio PPV (%) NPV (%) Diagnostic accuracy (%)
point value 95%CI point value 95%CI point value 95%CI point value 95%CI point value 95%CI point value 95%CI
WeDA System 94.55 83.93–98.58 98.18 89.01–99.91 0.93 52 7.45–362.98 0.06 0.02–0.17 935.99 98.11 88.62–99.90 94.74 84.45–98.63 96.36
SNAP-IV 76.36 62.67–86.34 80.36 67.16–89.33 0.57 3.89 2.24–6.74 0.29 0.18–0.48 13.22 79.25 65.5–88.70 77.59 64.40–87.08 78.18

NLR Negative likelihood ratio, NPV Negative predictive value, PLR Positive likelihood ratio, PPV Positive predictive value