Skip to main content
. 2022 Jun 22;13:3566. doi: 10.1038/s41467-022-31052-6

Fig. 3. Results in quantum illumination imaging.

Fig. 3

Experiment performed using a setup similar to this shown in Fig. 1a. in which another object illuminated by a classical light source (LED) is inserted. Images of both objects (positive and negative resolution charts) are superimposed onto the camera. a Intensity image, (b) diagonal image and (c) JPD pixel super-resolution image acquired using a camera with a 32 μm-pixel-pitch. d Intensity image, (e) diagonal image and (f) JPD pixel super-resolution image acquired using a camera with a 16 μm-pixel-pitch. The photon correlation width in the camera plane is σ ≈ 8 μm.