Skip to main content
. 2022 Jun 17;12(6):1484. doi: 10.3390/diagnostics12061484

Table 4.

Statistical measures of the pathologists’ performance on glass slides.

Senior Pathologist 1A Senior Pathologist 1B Senior Pathologist 2A Senior Pathologist 2B Pathologist A Pathologist B Resident A Resident B Our model
Sensitivity 0.9130 0.8695 0.9130 0.9565 0.5217 0.9565 0.4782 0.3478 0.9565
Specificity 1 1 0.9729 1 0.9729 0.9189 1 0.9459 1
Precision 1 1 0.9545 1 0.9230 0.88 1 0.8 1
Negative predictive value 0.9487 0.925 0.9473 0.9736 0.7659 0.9714 0.7551 0.7 0.9737
False negative rate 0.0869 0.1304 0.0869 0.0434 0.4782 0.0435 0.5217 0.6521 0.0435
False positive rate 0 0 0.0270 0 0.0270 0.0811 0 0.0540 0
Accuracy 0.9667 0.95 0.95 0.9833 0.8 0.9333 0.8 0.7166 0.9833
F1 0.9545 0.9302 0.9333 0.9778 0.6667 0.9167 0.6471 0.4848 0.9778
Experience (decades) 1.2 1.4 0.7 0.9 0.4 0.4 0 0 -