Table 2.
Mean values with standard deviation (SD) for image sharpness on EID, PCCT (QIR−) and PCCT (QIR+) images of enlarged lesions and the whole lung using a 5-point Likert scale as well as their associated p-values. Mean values are based on the rating on the Likert scale assessed by the readers (1—deficient, 2—sufficient, 3—satisfactory, 4—good, 5—very good). Statistical significance was assumed for p-values < 0.05.
EID | PCCT (QIR−) | PCCT (QIR+) | Stat. Significance (p) | |||
---|---|---|---|---|---|---|
Mean SD | Mean SD | Mean SD | EID vs. PCCT (QIR−) | EID vs. PCCT (QIR+) | PCCT (QIR−) vs. PCCT (QIR+) | |
Lesion | 3.3 ± 1.1 | 3.6 ± 0.8 | 3.9 ± 0.8 | 0.001 | <0.001 | 0.020 |
Whole Lung | 3.9 ± 0.9 | 4.1 ± 0.7 | 4.2 ± 0.8 | 0.236 | 0.014 | 0.167 |