Temperature-dependent thermal diffusivity (m2/s), specific heat capacity (J/g·K), and density (g/cm3), plus the calculated thermal conductivity (W/m·K) of the Gel-10% solution with their corresponding measurement uncertainties (Uc ).

Calculated Values Measured Values
T λ Uc (λ) a Uc (a) cp Uc(cp) ρ Uc(ρ)
T/°C λ/W/m·K a × 106/m2/s cp/J/g·K ρ/g/cm3
40 0.5227 0.089984 0.1338 0.016634 3.9012 0.037555 1.0015 0.11886
38 0.5107 0.073104 0.1344 0.018374 3.8035 0.082070 0.9987 0.036643
30 0.5115 0.068069 0.1382 0.010748 3.6897 0.381668 1.0030 0.031100
25 0.5017 0.143145 0.1396 0.009615 3.5070 0.969591 1.0250 0.015800
20 0.4546 0.052582 0.1386 0.010748 3.2011 0.258152 1.0250 0.030000
10 0.3479 0.147735 0.1394 0.010307 2.4340 1.015339 1.0250 0.030000
0 1.2885 0.148143 0.6227 0.021750 2.0189 0.213102 1.0250 0.030000
−10 1.5512 0.065615 0.7800 0.011077 1.9403 0.052454 1.0250 0.030000
−20 1.5784 0.071809 0.7999 0.024982 1.9251 0.029684 1.0250 0.030000
−30 1.5305 0.149932 0.8153 0.075092 1.8315 0.029336 1.0250 0.030000
−40 1.4766 0.817094 0.8230 0.454528 1.7504 0.031749 1.0250 0.030000