Table 1. Demographic information.

Measure Control CI users
Number of subjects (# of females) 18 (11) 20 (11)
Mean age at test in years (std) 57.57 (12.74) 56.80 (14.09)
Mean years of CI use (std) 8.10 (6.51)
Mean speech perception score (AzBio sentences in quiet) (std) 0.99 (0.01) 0.88 (0.09)
Mean right ear 4fPTA (std) 16.02 (6.74) 21.85 (5.30) with CI on
Mean left ear 4fPTA (std) 16.61 (7.67) 91.25 (26.77) unaided
Mean left ear 4fPTA at test*, (std) 73.28 (37.72)
Mean duration of deafness right ear 12.58 (11.74)

If no response at a given frequency, a value of 120 dB HL was assigned.

*

With hearing aid, if the subject used amplification. Eight out of 20 CI (cochlear implant) users used hearing aids.

4fPTA (four-frequency pure-tone average), average pure tone threshold at four frequencies (500, 1000, 2000, 4000 Hz).