The comparison of proposed CardioNet and other state-of-the-art methods for the MC dataset (unit: %).

Type Method Accuracy Jaccard Index Dice Coefficient
Handcrafted feature-based methods Vajda et al. [61] 69.0 - -
Candemir et al. [4] - 94.1 96.0
Peng et al. [55] 97.0 - -
Deep feature-based methods Feature selection and Vote [62] 83.0 - -
Feature selection with BN [62] 77.0 - -
Bayesian feature pyramid network [52] - 87.0 93.0
Souza et al. [30] 96.97 88.07 96.97
HybridGNet [57] 95.4
MPDC DDLA U-Net [59] 94.83 96.53
CardioNet (proposed method) 98.92 95.61 97.75