Table 6.
Decision rule for IC ARL 370 and steady-state size 1: choose TS over CUSUM FIR if (see Table 7) satisfies the inequality in a particular cell.
| 0.10 | 0.25 | 0.50 | 0.75 | 1.00 | 1.25 | 1.50 | |
|---|---|---|---|---|---|---|---|
| 0.20 | <976.5 | <1786.8 | <3863.9 | <8591.9 | <18579.7 | <23669.2 | <19243.1 |
| 0.50 | <262.1 | <232.1 | <585.1 | <1834.1 | <5400.6 | <9196.1 | <8186.0 |
| 1.00 | <133.6 | <66.2 | <76.9 | <222.6 | <734.5 | <1350.6 | <1472.5 |
| 1.50 | <93.8 | <42.4 | <30.3 | <61.0 | <175.1 | <307.0 | <362.2 |
| 2.00 | <73.7 | <33.0 | <19.2 | <29.1 | <66.9 | <111.7 | <114.9 |
| 2.50 | <61.2 | <27.9 | <15.1 | <19.0 | <34.9 | <48.7 | <46.5 |
| 3.00 | <52.7 | <24.6 | <13.1 | <14.9 | <23.8 | <27.2 | <23.2 |