Table 8.

Evaluation of the proposed severity detection method with other methods

Author Perfomance metric Value
Chaganti et al. Lung infection Pearson correlation coefficient 0.92 for percentage of opacity (P 0.001)
Shen et al. Severe non severe Pearson correlation coefficient ranged from 0.7679 to 0.837, P 0.05
Xiao et al. Severe non severe Precision AUC 81.3% 98.7%
Shan et al. Quatifying the infection regions Dice similarity coefficient 91.6% 10.0
Pu et al. Severity and progression Sensitivity specificity 95% 84%
Tang et al. Severe Non severe Accuracy 87.5%
Proposed Method (HGH, MODERATE, LOW) Accuracy 90.0%