Table 2.

Multi-variable logistic regression for RHF at 3 months post-implant*

Effect Odds ratio (95%CI) p-value
Pre-Implant Characteristics
 Previous TV Repair/Replacement 4.50 (2.01 −10.09) <0.001
 Severely depressed pre-operative RV function 1.60 (1.17 −2.20) 0.004
 Elevated Systolic Blood Pressure (>120 mmHg) 1.40 (1.07 −1.82) 0.014
 Blood urea nitrogen (mg/dL) 1.06 (1.03 −1.09) <0.001
 Pulmonary Diastolic Pressure (mmHg) 1.02 (1.01 −1.03) 0.004
 LVEF < 20% 0.75 (0.59 −0.94) 0.013
Implant Details
 Left ventricular centrifugal pump vs axial 1.43 (1.15 −1.78) 0.001
Post Implant Events
 RHF at 1 Month Post Implant 6.35 (5.13 −7.86) <0.001
 Sepsis Post Implant 2.74 (1.16 −6.50) 0.022
*

LVEF: left ventricular ejection fraction diameter; RHF: right heart failure; RV: right ventricular; TV: tricuspid valve. All variables shown in Supplemental Table 1 were potential covariates in the regression models.

Blood urea nitrogen represents a 5-unit increase