Skip to main content
. 2022 Jun 20;3(6):502–509. doi: 10.1302/2633-1462.36.BJO-2021-0212.R1

Table III.

Candidate item inclusion and acceptability threshold determination by Delphi round.

Item Round in which consensus was achieved Panel agreement, %
1a. Medial clear space 1 88
1b. Acceptable MCS ≤ 4 mm 2 76
2a. Medial malleolar displacement 1 96
2b. Acceptable MMD ≤ 2 mm 3 95
3a. Lateral malleolar displacement 1 96
3b. Acceptable LMD ≤ 2 mm 3 95
4a. Tibiofibular clear space 1 75
4b. Acceptable TFCS ≤ 5 mm 3 100
5a. Talocrural angle 3 95
5b. Acceptable = 80° ± 5 3 95
6a. Talar tilt angle Failed to reach consensus after 3 rounds > excluded
6b. Acceptable = N/A

LMD, lateral malleolar displacement; MCS, medial clear space; MMD, medial malleolar displacement; N/A, not applicable; TFCS, tibiofibular clear space.