Skip to main content
BMJ Case Reports logoLink to BMJ Case Reports
. 2022 Jun 28;15(6):e246515. doi: 10.1136/bcr-2021-246515

Unstable gynaecological patient with an ankle monitor: implications of US Immigration and Customs Enforcement’s Alternatives to Detention programme in the healthcare setting

Anna Pancheshnikov 1, Rohini Boddu 1, Leonard S Rubenstein 2, C Nicholas Cuneo 3,4,✉
PMCID: PMC9240831  PMID: 35764334

Abstract

We review the case of an unstable gynaecological patient in the USA who presented with profuse vaginal bleeding after spontaneous miscarriage and was ultimately diagnosed with a uterine arteriovenous malformation managed with interventional radiology embolisation of her uterine artery. Her case was complicated by the presence of an ankle monitoring device which had been placed by US Immigration and Customs Enforcement as part of the Alternatives to Detention programme in which she was enrolled during her immigration proceedings. The device prompted important considerations regarding the potential use of cautery, MRI compatibility and device-related trauma, in addition to causing significant anxiety for the patient, who was concerned about how the team’s actions could affect her immigration case. Discussion of her course and shared perspective highlights the unique clinical and medicolegal considerations presented by the expanded use of ankle monitoring devices for electronic surveillance (or ‘e-carceration’) of non-violent immigrants and others.

Keywords: Anxiety disorders (including OCD and PTSD), Migration and health, Obstetrics and gynaecology, Perioperative care, Global Health

Background

The US civil immigration detention system, which is responsible for monitoring immigrants as they move through immigration court proceedings through the conclusion of their case, is managed by the US Immigration and Customs Enforcement (ICE)’s Enforcement and Removal Operations (ERO). Some US immigrants are determined by ERO to be in need of custodial supervision and placed in detention facilities.1 In growing recognition of the harms of incarceration for non-violent individuals—particularly after the advent of the COVID-19 pandemic—ICE has faced increased pressure to release detainees deemed not to pose a threat to the community.2 Even so, 75% of the 21 952 individuals in ICE detention have no criminal record, and many who do have only minor offences, such as traffic violations.3 ICE has operated an Alternatives to Detention (ATD) programme since 2004, which uses intensive case management and surveillance technology, including electronic monitoring devices, with a ‘goal of more closely monitoring a small segment of cases assigned to the non-detained docket’.4 5 As of 12 February 2022, a total of 182 607 individuals were enrolled in ATD, including 28 793 with Global Positioning System (GPS)-enabled ankle monitoring devices (also known as ‘electronic ankle shackles’), 118 448 with SmartLINK (a facial recognition application for smartphones that allows for identity to be confirmed in addition to location monitoring) and 35 366 participating in telephonic reporting.6

Electronic monitoring devices, including ankle monitors, are considered a less humane ATD but have been in use by ICE’s Intensive Supervision Appearance Program (ISAP) III on thousands of immigrants with pending cases, especially as large numbers of people were released from physical detention during the COVID-19 pandemic.4 7 While ostensibly preferable to detention, ankle monitoring devices pose unique risks and stigma to individuals, with particular implications for the healthcare setting. Little is known about the physical and psychological consequences of these devices despite the spike in their use and there is a paucity of guidance about the devices’ practical implications as well as safety and management for both healthcare professionals and patients.7 Here we present a case of an immigrant patient with a spontaneous abortion complicated by massive haemorrhage due to a uterine arteriovenous malformation (AVM) wearing an ankle monitoring device during the time of her care.

Case presentation

A woman in her 30s who is a G2P1001 with a history of multiple unknown previous uterine surgeries in her Central American country of origin presented to the emergency department (ED) with an episode of profuse vaginal bleeding and decreasing beta-human chorionic gonadotropin (HCG) attributed to a spontaneous miscarriage. On initial presentation, her vaginal bleeding completely resolved spontaneously. Her beta-HCG was 94 and transvaginal ultrasound revealed no intrauterine gestation, no ectopic pregnancy and multiple dilated vessels to 10 mm in the myometrium, with probable involvement of the endometrium (figure 1). After an evaluation by the obstetrics and gynaecology team, a diagnosis of a pregnancy of unknown location, with a likely complete abortion, was made with an incidental finding of uterine AVMs. An ankle bracelet was noted on her right leg at the time of exam, which the patient explained was placed as part of her ATD programme, but was not considered to be clinically relevant at that time. She was discharged in stable condition with plan for repeat beta-HCG testing to confirm downtrend to non-pregnant levels. She was enrolled in a charitable care programme available for low-income, uninsurable patients, and close follow-up at the gynaecology clinic was arranged. She was counselled on her diagnosis and management plan, and although her bleeding episode was thought to be due to her miscarriage, the gynaecology team reviewed strict return guidelines as well as potential uterine AVM complications with her prior to discharge.

Figure 1.

Figure 1

Two-dimensional greyscale pelvic ultrasound transvaginal transverse (A) and longitudinal (B) views demonstrate anechoic structures (asterisks) within a dilated hyperechoic endometrial stripe (arrows), which nearly completely fill in on colour Doppler interrogation (C, D).

She presented 2 days later with profuse, active vaginal bleeding and became tachycardic and hypotensive in the ED, consistent with haemorrhagic shock. A massive transfusion protocol was initiated. She was transported to the operating room for an exam under anaesthesia and possible emergent hysterectomy in the setting of concern for uterine AVMs and active bleeding. At this time, the clinical implications of her ankle monitor were called into question. Considering clinicians’ and nurses’ previous experiences with implanted devices and jewellery intraoperatively, concern was raised about care limitations with the device in place including use of cautery during surgery and possible constriction-related injuries from the device in setting of perioperative fluid shifts. No specific guidelines about perioperative care with an ankle monitoring device were located, and on further research later on, it was determined that such specific guidelines do not exist in our hospital setting. The team discussed potential solutions such as wrapping padding between the device and the patient’s skin or removing the device, with the latter considered to be a safer choice. However, no easily identifiable method was evident for removal, without instructions or a 24-hour call line attached to the device, and there was hesitancy raised regarding the ramifications of removal for the patient: on hearing the discussion about removing the device, the patient—who was haemodynamically unstable at the time—sat up on the surgical table and expressed extreme trepidation regarding the implications of such an action on her immigration case. Unfortunately, due to the tense political climate, heightened ICE enforcement, no previous education or training on the topic, and inability to contact ICE in the middle of the night, the team was uncertain about the potential consequences of device removal, even in an emergency. Device removal was thus temporarily deferred in observance of the patient’s wishes.

The patient’s bleeding transiently subsided and her vital signs stabilised as she was being massively transfused, and thus plan for hysterectomy was suspended. At this point, consideration was given to the possibility of obtaining an emergent MRI to confirm the diagnosis of AVM and determine the extent of disease; however, this was contraindicated in the presence of her ankle monitoring device. She was ultimately transported to interventional radiology (IR) for emergent right uterine artery angiography through her right femoral artery, which confirmed the diagnosis of AVM (figure 2 and video 1). In this case, fortuitously, there was no significant delay or change in management due to the ankle monitoring device, as IR embolisation was an appropriate choice for a haemodynamically stable patient with a suspected bleeding AVM. However, such a delay or change in treatment could have resulted if the clinical situation had evolved differently; for example, if the patient remained haemodynamically unstable or if emergency IR services were unavailable at our institution. Additionally, we believe the uncertainty about the device’s safety and removal implications was a source of unnecessary and potentially harmful distraction for the clinical team throughout the patient’s care.

Figure 2.

Figure 2

Subtraction angiography of the right uterine artery sequential imaging (A–D) demonstrates tortuous uterine artery (thick arrow, A) with a nidus arising from a distal branch (arrowheads, B, C) with early-filling veins (thin arrows, D). Findings are compatible with arteriovenous fistula.

Video 1.

Disclaimer: this video summarises a scientific article published by BMJ Publishing Group Limited (BMJ). The content of this video has not been peer-reviewed and does not constitute medical advice. Any opinions expressed are solely those of the contributors. Viewers should be aware that professionals in the field may have different opinions. BMJ does not endorse any opinions expressed or recommendations discussed. Viewers should not use the content of the video as the basis for any medical treatment. BMJ disclaims all liability and responsibility arising from any reliance placed on the content.

DOI: 10.1136/bcr-2021-246515.video01

Two metallic coils were successfully placed via superselective catheterisation, after which she was admitted to the surgical intensive care unit (SICU) for further monitoring (figure 3 and video 2). She was extubated on postoperative day 1, at which time her ankle monitoring device was noted to be out of battery (the SICU team was unaware of the need to recharge the device and lacked the equipment to do so). When the patient realised her device had run out of batteries—an issue that can lead to disciplinary action—she became gravely concerned. At the patient’s request, the consulting gynaecology team contacted her ICE case worker to inform him of her hospitalisation and inquire about protocol for removal of the device in the setting of the patient’s condition and in case of potential need for further imaging and/or surgical management. The ICE caseworker informed the medical team that he was able to call the patient to confirm her location and that the ankle monitor could be removed immediately in any emergency without legal ramifications, though with preference for early notification if possible. At that time, the primary SICU team did not deem it medically necessary to remove the device, as had been suggested by the consulting gynaecology team.

Figure 3.

Figure 3

Subtraction angiography of the right uterine artery superselective catheterisation (A) with placement of two metallic coils (B). Angiogram of the uterine artery post embolisation (C) demonstrates no venous nidus or early filling veins in keeping with successful arteriovenous fistula embolisation.

Video 2.

Disclaimer: this video summarises a scientific article published by BMJ Publishing Group Limited (BMJ). The content of this video has not been peer-reviewed and does not constitute medical advice. Any opinions expressed are solely those of the contributors. Viewers should be aware that professionals in the field may have different opinions. BMJ does not endorse any opinions expressed or recommendations discussed. Viewers should not use the content of the video as the basis for any medical treatment. BMJ disclaims all liability and responsibility arising from any reliance placed on the content.

DOI: 10.1136/bcr-2021-246515.video02

On postoperative day 3, the patient expressed severe, increasing right leg pain and swelling—a ‘weighing down’ of the leg and discomfort under the ankle device, which was not well controlled despite a multimodal pain control regimen. Physical exam revealed bilateral lower extremity oedema, with the monitoring device exerting direct pressure on her right ankle. The SICU team ordered an upper and lower venous Doppler ultrasound, which was negative for thromboses and, after examination by the IR team, the pain was not thought to be due to a postprocedural complication. After consultation with the gynaecology team, who informed the ICE case worker, and shared decision-making with the patient, her monitor was removed using bolt cutters with the help of the hospital security team. The following day, her right leg pain improved and eventually resolved, and it was felt to be due to the pressure the ankle device was exerting on her oedematous limb. Of note, prior to removing the device (an option previously confirmed as viable by the ICE case officer), multiple clinical studies and interventions, in retrospect unnecessary, were attempted, further revealing the confusion that the ankle monitor caused to the multidisciplinary care team. The patient remained stable throughout the remainder of her hospital stay. A subcutaneous etonogestrel implant was inserted for contraception and she was discharged on postoperative day 7. She was followed up closely with no further bleeding, pain or concerns, and beta-HCG decreased to a non-pregnant level. The patient is currently doing well, with intermittent spotting for which she is being evaluated by the gynaecology clinic, but no further excessive bleeding or pain. Since the removal of her ankle monitor, she has been transitioned to telephonic reporting for her ICE ATD monitoring and is currently in removal proceedings in which she is applying for relief.

Global health problem list

  • Ankle monitoring devices are being employed by immigration authorities amid a dynamic and chaotic immigration enforcement environment, posing ethical challenges for healthcare professionals

  • The presence of an ankle monitoring device can have clinical and medicolegal implications on a patient’s care plan, including safety concerns surrounding the use of monopolar electrocautery, potential for device-related pressure injuries, restrictions in available imaging modalities, and patient privacy concerns

  • There is a paucity of education, training and protocols available to guide healthcare professionals in the safe care of patients with ankle monitoring devices and a lack of information for individuals with the device to instruct them on device-related practical and logistical issues in the healthcare setting

  • Patients with ankle monitoring devices can face stigma in the community and in healthcare settings and may experience significant anxiety and distrust related to how ankle monitoring devices might affect their medical care and how medical decisions regarding these devices could impact their immigration proceedings

Global health problem analysis

Dynamic and chaotic immigration enforcement environment

Guidance regarding the punitive consequences of removal of monitoring devices, when present, typically exempts device removal in the setting of medical care or emergency response.8 There is increasing consensus across the profession that even in the common case of shackled prisoners, for whom similar ambiguity in formal guidance exists, shackles should be removed whenever possible, particularly during the physical exam or while under general anaesthesia.9–11 Unfortunately, even in the few cases where law and policy are quite clear, such as in legislature prohibiting perinatal shackling for female prisoners, studies suggest that shackling of incarcerated women during pregnancy and postpartum continues and that most nurses are not aware of state laws and/or medical society statements about this practice.12 13 Furthermore, there have been publicised cases of immigrants being deported after accusations of tampering with their ankle monitoring devices, even in the setting of documented medical necessity.14 There is an urgent need for clear federal and agency guidance on the implications of use and removal of ankle monitoring devices in healthcare settings and for primary and continuing education regarding the provision medical care for patients with these devices.

Clinical and medicolegal implications

In the presented case, the patient’s ankle monitoring device posed questions and possible limitations with respect to four treatment considerations: (1) the appropriate use of cautery intraoperatively and whether its use would be limited by the device, (2) the safety of MRI use with the device, (3) concern for lower extremity swelling and constriction by the device in the setting of volume resuscitation, and (4) patient privacy considerations and Health Insurance Portability and Accountability Act (HIPAA) rules when informing ICE case officers about the need for device removal.

With respect to the use of intraoperative cautery, there is little published research on the specific topic of ankle monitoring devices, though many theoretical considerations and potential extrapolations emerge from the literature on other devices, such as automatic implantable cardioverter defibrillators and jewellery.15–18 Specifically, with monopolar electrocautery (eg, Bovie cautery), commonly used in surgical procedures, the patient becomes part of the electrical circuit, which is grounded by a pad also placed on the patient. The electromagnetic circuit has been shown to cause interference with other electrical equipment in the operating room or on the patient, such as implantable cardiac devices or potentially ankle monitoring devices, leading to damage to the device or, more concerningly, burns or other bodily harm to the patient.18 To prevent adverse outcomes without removing the device, the Association of Perioperative Registered Nurses (AORN), as well as limited literature published in anaesthesia journals, recommends applying the grounding pad to the contralateral limb (close to the surgical site and not in the current pathway), placing padding between the skin and the device, setting the electrocautery to a low frequency, or use of an alternative cutting and coagulation method such as bipolar cautery, wherever possible.18 19 However, both anaesthesia and perioperative nursing associations agree that removal of the device prior to the procedure is the best way to prevent injury, and securing permission from the responsible law enforcement agency should not delay emergency surgery or interfere with patient safety considerations.19

Similarly, little is known about potential adverse outcomes from direct pressure injuries, positioning-related injuries, injuries related to oedema, and interference with surgical site or procedural antiseptic preparation from the ankle monitoring device. Some evidence suggests ankle monitoring devices have caused skin irritation, infection and even septic malleolar bursitis, a rare cause of ankle pain and swelling requiring needle aspiration and antibiotic therapy.20 Additionally, a recent survey of people directly affected by ankle monitors reports the wide majority (90%) experience some physical harm from the device, including pain, numbness from impaired circulation or cuts from continuous chafing.7 Information extrapolated from dealing with jewellery perioperatively and during prolonged hospitalisations again suggests the importance of establishing device-specific evaluation and removal policies and procedures.19 For example, prior to a planned surgical intervention, patients are provided with instructions on jewellery removal; however, when faced with emergent surgical intervention, AORN recommends taping, padding and close monitoring of jewellery.19 Despite using this extrapolated knowledge in our patient and healthcare providers advocating for device removal due to the aforementioned concerns, the healthcare providers had no federal, ICE or hospital guidelines on how to proceed, including no information on device removal logistics.

Though device specifications vary by manufacturer and model, ankle monitors are not generally considered to be MRI-compatible and therefore must be removed prior to the imaging procedure. They can also interfere with CT or X-ray imaging of the affected limb. For example, one manufacturer of an ankle monitoring device instructs individuals to contact their supervisor to remove the device before any MRI, X-ray or CT scan.21 While in many cases MRIs and other imaging studies are conducted on an outpatient basis, in urgent or emergent cases (eg, concern for cerebrovascular accident or spinal cord compression), it may not be possible to reach the responsible law enforcement agency in time and device removal should not be delayed.

HIPAA, privacy and medical ethics concerns can also arise as healthcare providers make clinical and safety decisions associated with removal of an ankle monitoring device and potentially contact ICE to inform agents of device removal.22 As in the case of incarcerated individuals whose identifiable health information is specifically not excluded from the definition of protected health information according to the HIPAA of 1996, confidentiality must be maintained in accordance to patients’ wishes.10 In our case, the patient provided consent to our sharing her hospitalisation details with her ICE case worker, and only limited information was shared on a need-to-know basis. However, the question arises regarding patients who may refuse sharing of such information or patients who may feel obligated to share health information for fear of negative consequences on their immigration case, and how healthcare providers might respond to the medical need of device removal while fully protecting patient privacy. Additionally, higher levels of mistrust of the medical system already exist among ethnic minorities.10 These can be exacerbated by concerns about privacy for patients with ankle monitoring devices, contributing to reluctance to seek care among these patients or hesitancy to report discomfort, pain or other issues with the ankle monitoring devices.

Paucity of guidance, education and training

Despite the large number of patients who wear an ankle monitor as part of their ATD conditions and multiple potential clinical issues such as perioperative safety, imaging compatibility and harmful physical consequences of the ankle device, there is a paucity of knowledge on the impact of immigration-related law enforcement among healthcare professionals.23 Education and training efforts on the topic of care of ‘shackled’ patients and updates on relevant federal and state law are lacking in medical schools and hospital settings.13 23 This gap in knowledge was clear in our case at multiple occasions: among the perioperative team on being confronted with questionable safety of the ankle device during emergency surgery, among the gynaecology and radiology team when deciding on a proper imaging study for the patient, and among the ED, gynaecology, SICU and security teams, as well as the patient herself, when considering the physical logistics and legal ramifications of device removal. In such a case, when dealing with an emergency, the lack of guidance, education and training caused confusion and ineffective patient counselling; for example, the team was unable to reassure the patient in a timely manner that removal of the device would not negatively affect her immigration case.

On further research in the ED, perioperative patient safety, radiology and security departments, no guidelines or protocols were identified specific to the care of patients with ankle monitors. This is in line with recent data from a national survey of healthcare providers in the USA, in which 82.5% were unaware of any policies or procedures relevant to immigration-related law enforcement activity in their places of work.23 In fact, there is no high-quality evidence specific to ankle monitor safety in the operating room or in other clinical settings.19

Rather, extrapolated information from guidelines on care of patients with other ‘devices’ such as jewellery, dentures, contacts and hearing aids is usually adopted, which, while useful, is not always comparable (eg, no potential legal implications for removal of jewellery and no typical logistical difficulty with removing hearing aids). Written guidelines about clinical implications of ankle monitoring devices are also absent among key stakeholders such as ICE, ISAP, ankle monitoring device companies and diathermy manufacturers. On contact with ankle monitoring device companies about practical and clinically relevant information pertaining to the device, responses ranged from declining to answer to only basic information available on frequently asked questions pages such as instruction to immediately cut the strap and remove the bracelet in case of a medical emergency, and potential incompatibility with medical imaging or medical devices.21

According to the ICE/ISAP officials we contacted, although some training about medical emergencies is provided to organisation officers, no formal written protocols or policies exist on the matter. Additionally, medical device companies such as Medtronic—a manufacturer of electrosurgical hardware products—do not have specific instructions on use of their devices in patients with ankle monitoring devices. Essential information about practical and clinically relevant concerns relating to ankle monitor use is lacking for both healthcare professionals and individuals wearing these devices.

Stigma inside and outside the healthcare setting

As illustrated by our patient in her perspective as follows, as well as in a recent national survey, a final and important consideration is the psychological harm, trauma, isolation and anxiety ankle monitoring devices can cause individuals.7 Particularly in the medical setting, patients with ankle monitoring devices may experience a heightened sense of stigmatisation and fear the potential consequences of their device’s removal or malfunctioning (eg, due to inadequate charge) with respect to immigration or other law enforcement proceedings.24 In the case of individuals wearing these devices as part of an ATD programme for immigration proceedings, some may feel they are judged and perceived as ‘criminals’ due to the use of ankle monitoring devices across other law enforcement proceedings, including individuals convicted of violent crime (eg, after they are released on parole).7 24 In fact, the common Spanish term for these devices (‘grilletes’) translates directly to ‘shackles’.25 26 Given that many migrants have escaped situations of trauma and violence, ankle monitors can further serve as a painful reminder of past trauma and exacerbate mental illness such as posttraumatic stress disorder (PTSD), anxiety and depression.7 27 To overcome the stigma and social isolation associated with the sighting of an ankle monitoring device and related device alarms, reports indicate that ATD participants place an emphasis on concealing the visibility of the ankle monitoring device.7 In light of these combined forces, it is critical that providers engage in a trauma-informed approach with patients wearing these devices, ensuring open communication and centring the patient’s preferences wherever possible.

Patient’s perspective.

I felt very bad because I thought that because of the GPS tracker I would be denied care [at the hospital] and that I would bleed to death. I also was so scared and uncomfortable at the hospital because I knew the GPS tracker had to be charged at all times, and that because I was at the [ICU] and my GPS could not be charged, the migration officials were going to come [and arrest me]. I felt very, very scared.

When I became sick and [started bleeding] I thought that I would not get any assistance, neither financial nor medical [at the hospital] because I thought that due to having the GPS trackers [while having a medical emergency] I would be sent back to my country. I was in so much pain, and [it was only made worse] by this terrible worry I had about the GPS tracker [and what it would mean for me]. All of this made me feel scared, sad, and most of all, alone, very much alone. (Translated from Spanish)

Learning points.

  • Healthcare providers must take into account potential clinical considerations—such as anticipated use of cautery, need for MRI and potential consequences of pressure, positioning and oedema-related injuries—when treating patients with ankle monitoring devices and deciding whether such devices can remain in place without compromising patient care. Advanced permission for removal (eg, from the patient’s Immigration and Customs Enforcement (ICE)/Intensive Supervision Appearance Program (ISAP) case manager) can be sought if medically appropriate and desired by the patient. Hospital security teams can be involved to facilitate removal of these devices.

  • Hospitals are considered ‘sensitive locations’ for immigration enforcement activities by both ICE and Customs and Border Protection (CBP); however, actions taken by healthcare professionals in these settings (eg, removal or neglect of an Alternatives to Detention device) can be used against patients if proper explanatory communication with the appropriate authority is not achieved, and thus authorities are unaware of the medical/safety reasons for removal of the device. Communication with appropriate authorities should be sought according to patient preferences after informing them of their privacy rights as protected by the Health Insurance Portability and Accountability Act but should not delay exigent medical or patient safety decisions in emergency settings.

  • Device removal for medical reasons is protected under some state-level regulations, but such protections may vary considerably and are typically contingent on approval from ICE/ISAP. There is an urgent need for formalising protections in cases of medical emergencies that stipulate device removal by the healthcare team as well as additional guidance, education and training for healthcare providers for non-emergent cases in which patient consent for communication with relevant authorities cannot be obtained. In the case of patients declining removal against medical advice or inability to remove the device, clinicians can use reported innovations to promote safer use of monopolar electrocautery as well as extrapolated precautions for prevention of burn, pressure or positioning injuries. However, these workarounds are not well studied, and there remains a theoretical risk to the patient.

  • Patients who are compelled to wear ankle monitoring devices as part of their immigration proceedings may have a history of trauma or perceived stigma which can be exacerbated in the setting of these devices, and trust issues with medical teams may consequently arise. It is important for healthcare providers to employ a trauma-informed approach to patient care wherever possible in managing these patients with special attention to cultural humility and language-concordant care.

Acknowledgments

We thank Dr Cristina Ivette Olivas Chacon, an instructor in radiology at Johns Hopkins, for providing key assistance in identifying and captioning key figures and videos for this case. We also thank Dr C C Grace Chen and the patient for their generous support, which was essential to the publication of this case.

Footnotes

Twitter: @nickcuneo

Presented at: North American Refugee Health Conference; June 25, 2022; Cleveland, Ohio, USA.

Contributors: AP and RB cared for the patient directly, assisted in drafting the manuscript and served as joint first authors. LSR provided legal guidance/review for the manuscript and substantial contributions to the ethical analysis and framework for the case. CNC contributed significantly to case conceptualisation, assisted in drafting the manuscript, and served as senior and corresponding author.

Funding: The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

Case reports provide a valuable learning resource for the scientific community and can indicate areas of interest for future research. They should not be used in isolation to guide treatment choices or public health policy.

Competing interests: None declared.

Provenance and peer review: Not commissioned; externally peer reviewed.

Ethics statements

Patient consent for publication

Consent obtained directly from patient(s).

References

  • 1.U.S. Immigration and Customs Enforcement . Ice national detention standards (NDS) 2019, 2019. Available: https://www.ice.gov/doclib/detention-standards/2019/nds2019.pdf
  • 2.The Editorial Board . Opinion : ICE is the superspreader agency. The Washington Post, 2021. Available: https://www.washingtonpost.com/opinions/ice-is-the-superspreader-agency/2021/05/01/eb079944-a9f2-11eb-8c1a-56f0cb4ff3b5_story.html
  • 3.TRACImmigration . Immigration detention quick facts, 2021. [Google Scholar]
  • 4.Singer A. Immigration: Alternatives To Detention (ATD) programs. Key Congressional Reports for July 2019: Part II, 2019: 137–63. [Google Scholar]
  • 5.U.S. Immigration and Customs Enforcement . Detention management, 2021. [Google Scholar]
  • 6.TRACImmigration . Over 180,000 Immigrants Now Monitored by ICE’s Alternatives to Detention Program, 2022. Available: https://trac.syr.edu/immigration/reports/678/ [Accessed 12 Jun 2022].
  • 7.Giustini T, Greisman S, Markowitz PL. Immigration cyber prisons: ending the use of electronic ankle Shackles. New York, New York, 2021. Available: https://larc.cardozo.yu.edu/cgi/viewcontent.cgi?article=1002&context=faculty-online-pubs [Accessed 26 May 2022].
  • 8.Hollingsworth D. SB-566 monitoring devices: unauthorized removal, disabling, or tampering, 2009. [Google Scholar]
  • 9.Douglas AD, Zaidi MY, Maatman TK, et al. Caring for incarcerated patients: can it ever be equal? J Surg Educ 2021;78:e154–60. 10.1016/j.jsurg.2021.06.009 [DOI] [PubMed] [Google Scholar]
  • 10.Scarlet S, Dreesen E. Surgery in Shackles: what are surgeons' obligations to incarcerated patients in the operating room? AMA J Ethics 2017;19:939–46. 10.1001/journalofethics.2017.19.9.pfor1-1709 [DOI] [PubMed] [Google Scholar]
  • 11.Robinson M, Lavere K, Porsa E. End the routine Shackling of incarcerated inpatients. J Hosp Med 2021;16:376–7. 10.12788/jhm.3581 [DOI] [PubMed] [Google Scholar]
  • 12.Dignam B, Adashi EY. Health rights in the balance: the case against perinatal shackling of women behind bars. Health Hum Rights 2014;16:13–23. [PubMed] [Google Scholar]
  • 13.Goshin LS, Sissoko DRG, Neumann G, et al. Perinatal Nurses’ Experiences With and Knowledge of the Care of Incarcerated Women During Pregnancy and the Postpartum Period. Journal of Obstetric, Gynecologic & Neonatal Nursing 2019;48:27–36. 10.1016/j.jogn.2018.11.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Bernstein J. Caseworkers say ice accused women of tampering with ankle monitors, leading to their Deportations. Latino USA, 2020. [Google Scholar]
  • 15.Healey JS, Merchant R, Simpson C, et al. Society position statement : Canadian Cardiovascular Society/Canadian Anesthesiologists' Society/Canadian Heart Rhythm Society joint position statement on the perioperative management of patients with implanted pacemakers, defibrillators, and neurostimulating devices. Can J Anaesth 2012;59:394–407. 10.1007/s12630-012-9678-8 [DOI] [PubMed] [Google Scholar]
  • 16.Robinson TN, Varosy PD, Guillaume G, et al. Effect of radiofrequency energy emitted from monopolar "Bovie" instruments on cardiac implantable electronic devices. J Am Coll Surg 2014;219:399–406. 10.1016/j.jamcollsurg.2014.03.060 [DOI] [PubMed] [Google Scholar]
  • 17.Senthuran S, Toff WD, Vuylsteke A, et al. Implanted cardiac pacemakers and defibrillators in anaesthetic practice. Br J Anaesth 2002;88:627–31. 10.1093/bja/88.5.627 [DOI] [PubMed] [Google Scholar]
  • 18.Sarpong Y, Daga A, Sharar SR. Safety of electronic home monitoring devices in the operating room. The Internet Journal of Anesthesiology 2010;29. [Google Scholar]
  • 19.Burlingame BL. Clinical issues. Aorn J 2020;111:445–52. 10.1002/aorn.13003 [DOI] [PubMed] [Google Scholar]
  • 20.Besinger B, Ryckman S. Septic Malleolar bursitis in a patient with an ankle electronic monitoring device: a case report. Clin Pract Cases Emerg Med 2021;5:97-100. 10.5811/cpcem.2020.12.50299 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Frequently asked questions for SCRAM participants. SCRAM systems. Available: https://www.scramsystems.com/frequently-asked-questions/ [Accessed 26 May 2022].
  • 22.Stoughton S, Hampton K. Not in my exam room: how us immigration enforcement is obstructing medical care, 2019. Available: https://phr.org/our-work/resources/not-in-myexam-room/
  • 23.La Charite J, Braverman DW, Goplerud D, et al. Healthcare Professionals’ Experience, Training, and Knowledge Regarding Immigration-Related Law Enforcement in Healthcare Facilities: An Online Survey. J Law Med Ethics 2021;49:50–8. 10.1017/jme.2021.9 [DOI] [PubMed] [Google Scholar]
  • 24.Kilgour L. The ethics of aesthetics: stigma, information, and the politics of electronic ankle monitor design. The Information Society 2020;36:131–46. 10.1080/01972243.2020.1737606 [DOI] [Google Scholar]
  • 25.Pittman J. Released into Shackles: the rise of immigrant E-Carceration. California Law Review 2020;108:587–617. [Google Scholar]
  • 26.Martinez-Aranda MG. Extended punishment: criminalising immigrants through surveillance technology. Journal of Ethnic and Migration Studies 2020:1–18. [Google Scholar]
  • 27.Cuneo CN, Huselton KE, Praschan NC, et al. What Counts As ‘Safe?’: Exposure To Trauma And Violence Among Asylum Seekers From The Northern Triangle. Health Aff 2021;40:1135–44. 10.1377/hlthaff.2021.00082 [DOI] [PubMed] [Google Scholar]

Articles from BMJ Case Reports are provided here courtesy of BMJ Publishing Group

RESOURCES