Table 2. Related Data of EP and Its Composites from UL-94, LOI, and CCT at 35 kW/m2.
sample | UL-94 test | LOI (%) | PHRR (kW/m2) | THR (kW/m2) | TSP (m2) | PCOP (g/s) | av-EHC (MJ/K) | Char (wt %) |
---|---|---|---|---|---|---|---|---|
EP | NR | 25.4 ± 0.2 | 1133.0 ± 52 | 92.2 ± 2.0 | 20.6 ± 1.2 | 0.053 ± 0.002 | 27.5 ± 1.5 | 11.4 ± 0.5 |
EP/2ZIF67@ ZIF8 | V-1 | 28.1 ± 0.1 | 958.3 ± 41 | 73.8 ± 1.8 | 16.7 ± 0.7 | 0.039 ± 0.002 | 26.2 ± 0.8 | 13.5 ± 1.2 |
EP/2PA-ZIF67@ZIF8 | V-1 | 27.7 ± 0.3 | 1078.9 ± 31 | 80.2 ± 0.7 | 17.2 ± 0.8 | 0.038 ± 0.001 | 26.9 ± 1.2 | 13.8 ± 2.1 |
EP/5ZIF67@ ZIF8 | V-0 | 28.5 ± 0.2 | 700.6 ± 41 | 67.8 ± 1.2 | 15.4 ± 0.5 | 0.032 ± 0.002 | 24.7 ± 2.0 | 22.9 ± 1.7 |
EP/5PA-ZIF67@ZIF8 | V-0 | 29.3 ± 0.4 | 651.5 ± 37 | 61.8 ± 3.2 | 15.0 ± 0.7 | 0.029 ± 0.002 | 23.2 ± 1.9 | 25.4 ± 1.3 |