Table 2. Related Data of EP and Its Composites from UL-94, LOI, and CCT at 35 kW/m2.

sample UL-94 test LOI (%) PHRR (kW/m2) THR (kW/m2) TSP (m2) PCOP (g/s) av-EHC (MJ/K) Char (wt %)
EP NR 25.4 ± 0.2 1133.0 ± 52 92.2 ± 2.0 20.6 ± 1.2 0.053 ± 0.002 27.5 ± 1.5 11.4 ± 0.5
EP/2ZIF67@ ZIF8 V-1 28.1 ± 0.1 958.3 ± 41 73.8 ± 1.8 16.7 ± 0.7 0.039 ± 0.002 26.2 ± 0.8 13.5 ± 1.2
EP/2PA-ZIF67@ZIF8 V-1 27.7 ± 0.3 1078.9 ± 31 80.2 ± 0.7 17.2 ± 0.8 0.038 ± 0.001 26.9 ± 1.2 13.8 ± 2.1
EP/5ZIF67@ ZIF8 V-0 28.5 ± 0.2 700.6 ± 41 67.8 ± 1.2 15.4 ± 0.5 0.032 ± 0.002 24.7 ± 2.0 22.9 ± 1.7
EP/5PA-ZIF67@ZIF8 V-0 29.3 ± 0.4 651.5 ± 37 61.8 ± 3.2 15.0 ± 0.7 0.029 ± 0.002 23.2 ± 1.9 25.4 ± 1.3