Table 2. Internal test results for the bone suppression methods used in this study.
| Bone suppression method | PSNR (higher is better, mean ± SD) | SSIM (higher is better, mean ± SD) | RMSE (lower is better, mean ± SD) |
|---|---|---|---|
| None | 32.9±3.0 | 0.982±0.005 | 0.024±0.010 |
| Gusarev | 33.8±2.9 | 0.984±0.004 | 0.022±0.010 |
| Rajaraman | 34.0±3.7 | 0.986±0.004 | 0.021±0.010 |
PSNR, peak signal-to-noise ratio; SD, standard deviation; SSIM, structural similarity index measure; RMSE, root-mean-squared error.