Accuracy and area under the receiver operating characteristic curve (AUC) of different models.

Model Embedding method AUC, mean (SD) Accuracy, mean (SD) P value
XGBoost XGBoost 0.718 (0.0014) 0.892 (0.002)
  • N/Aa

XGBoost1 XGBoost+CCb 0.785 (0.0012) 0.919 (0.002)
  • <.001 vs XGBoost

XGBoost2 XGBoost+CC+HPIc 0.817 (0.0023) 0.928 (0.001)
  • <.001 vs XGBoost

  • <.001 vs XGBoost1

XGBoost3 XGBoost+CC+HPI+FHd 0.822 (0.0024) 0.934 (0.002)
  • <.001 vs XGBoost

  • <.001 vs XGBoost1

  • <.001 vs XGBoost2

aN/A: not applicable.

bCC: chief complaints.

cHPI: history of present illness.

dFH: family history.