Skip to main content
. 2022 Jun 20;12:911426. doi: 10.3389/fonc.2022.911426

Table 3.

Results obtained by the RF models constructed with different datasets.

Datasets AUC Precision Recall F1-score Accuracy
Micro-average Macro-average
T2WI 0.940 0.840 0.790 0.800 0.790 0.800
DWI 0.920 0.840 0.800 0.830 0.800 0.830
ADC 0.920 0.780 0.800 0.810 0.800 0.810
Merge 0.930 0.900 0.840 0.850 0.880 0.850