Skip to main content
. Author manuscript; available in PMC: 2024 Jan 1.
Published in final edited form as: Clin Gastroenterol Hepatol. 2022 Jan 6;21(1):136–142. doi: 10.1016/j.cgh.2021.12.047

Table 4:

Accuracy of Off State levels in diagnosing CHE in the test set of the derivation cohort (n=99) and validation cohort (n=94) based on formula created from the training set of the derivation cohort (n=299)

Total Stroop Time (Off+On) Off 1 through 2 Off 1 through 3 Off 1 through 4 Off1 through 5
Test Set
(n = 99)
Validation cohort
(n = 94)
Test Set
(n = 99)
Validation cohort
(n = 94)
Test Set
(n = 99)
Validation cohort
(n = 94)
Test Set
(n = 99)
Validation cohort
(n = 94)
Test Set
(n = 99)
Validation cohort
(n = 94)
Accuracy 81.82% 80.85% 77.78% 84.04% 77.78% 82.98% 77.78% 81.91% 79.80% 80.85%
Sensitivity 75.00% 62.50% 70.83% 75.00% 68.75% 66.67% 66.67% 66.67% 72.92% 62.50%
Specificity 88.24% 87.14% 84.31% 87.14% 86.27% 88.57% 88.24% 87.14% 83.33% 87.14%