Decision Table (RDS Table) for BOIN12 assuming the upper toxicity limit ϕT to be 0.35 and the lower efficacy limit ϕE to be 0.25 and the utility specification given in Table 1 of Lin et al. [21].

No of Patients No of Toxicities No of Efficacies Desirability Score
0 0 0 60
3 0 0 35
3 0 1 55
3 0 2 76
3 0 3 91
3 1 0 24
3 1 1 44
3 1 2 63
3 1 3 80
3 2 0 13
3 2 1 31
3 2 2 48
3 2 3 69
3 3 Any ED
6 0 0 22
6 0 1 38
6 0 2 51
6 0 3 67
6 0 4 81
6 0 5 93
6 0 6 100
6 1 0 15
6 1 1 27
6 1 2 42
6 1 3 56
6 1 4 72
6 1 5 87
6 1 6 96
6 2 0 8
6 2 1 19
6 2 2 34
6 2 3 47
6 2 4 64
6 2 5 77
6 2 6 90
6 3 0 4
6 3 1 12
6 3 2 22
6 3 3 38
6 3 4 51
6 3 5 67
6 3 6 81
6 4 0 1
6 4 1 6
6 4 2 15
6 4 3 27
6 4 4 42
6 4 5 56
6 4 6 72
6 ≥5 Any ED

ED means the dose should be eliminated because it does not satisfy the safety and efficacy admissible criteria (i.e., not admissible because of high toxicity or low efficacy).