Skip to main content
. 2022 Jun 22;7(26):22804–22810. doi: 10.1021/acsomega.2c02432

Table 5. Performance of the Bridging Cross-Linked Plugging Agent.

crack width, mm thickness of the filter cake, cm weight of the filter cake, g forward pressure-bearing capacity, MPa anti-return liquid capacity, MPa
1 1.0 376 16.0 5.5
2 1.5 459 17.0 4.5
3 2.0 583 11.0 4.0