Table 5.
Author and Year | Immersion Media/Surface Treatment | Immersion/Exposure Duration/Aging | Mean Change in Color of Conventional Polymerized Resin | Mean Change in Color of CAD/CAM Milled Provisional Resin | Mean Change in Color of 3D-Printed Provisional Resin | Instrument Used | Authors Suggestions/Conclusions |
---|---|---|---|---|---|---|---|
Yao et al., 2021 [45] | (i) Control (no surface treatment) (ii) Polishing (iii) Polishing + Optiglaze coating (iv) Polishing + Skinglaze coating |
Aging: Thermocycling: 5000 cycles at 5–50 °C (simulating 6 months of physiological aging) |
N/A | ΔE (i) 2.38 ± 0.44 (ii) 1.83 ± 0.51 (iii) 1.01 ± 0.38 (iv) 1.85 ± 0.78 |
ΔE (i) 3.83 ± 0.71 (ii) 2.66 ± 0.89 (iii) 1.37 ± 0.67 (iv) 1.40 ± 0.73 |
Digital spectrophotometer (Vita Easyshade V) |
|
Shin et al., 2020 [28] | Immersion media: (i) Grape juice (ii) Coffee (iii) Curry (iv) Distilled water |
Upto 30 days inside a 37 °C (simulating 2.5 years) | N/A | ΔE00 Between 0.64 and 4.12 |
ΔE00 Between 4.47 and 22.85 |
colorimeter (Minolta Cr321 Chromameter) |
|
Song et al., 2020 [44] | Immersion media: (i) Coffee (ii) Black tea |
Week: 1,2,4,8,12 | ΔE after week 12 (A) Alike: 9.89 ± 1.95 (coffee) 14.69 ± 3.05 (Black Tea) (B) Luxatemp Automix plus: 4.20 ± 1.57 (coffee) 6.52 ± 2.50 (Black Tea) |
ΔE after week 12 (C) PMMA Disk: 10.35 ± 1.14 (coffe(E) 16.66 ± 3.05 (Black Tea) (D) Telio CAD: 21.07 ± 2.86 (coffee) 24.60 ± 4.30 (Black Tea) |
ΔE after week 12 (E) VeroGlaze: 19.80 ± 2.85 (coffe(E) 16.90 ± 2.20 (Black Tea) (F) E-dent 100: 20.01 ± 3.00 (coffee) 22.13 ± 3.51 (Black Tea) |
spectrocolorimeter (Xrite Benchtop Spectrophotometer) |
|
Taşın et al., 2021 [48] | Surface treatment: (i) conventional polishing (ii) surface sealant—biscover LV Immersion Media: (A) distilled water (B) Cola (C) Coffee (D) Red Wine |
Days: 1, 7 & 30 | ΔE00 after 30 days PT & CAT Threshold values ## (A) Temdent Classic (i) Polished: Distilled water (1.87): > PT Cola (3.29), Coffee, Wine > CAT (ii) Surface sealant: Distilled water < PT Cola < CAT Coffee, Wine > CAT (B) Protemp 4 (i) Polished: Distilled water: > PT Cola, Coffee, Wine > CAT (ii) Surface sealant: Distilled water (1.34): < PT Cola (2.54) < CAT Coffee, Wine > CAT |
ΔE00 after 30 days (C) Duo Cad: (i) Polished: Distilled water: < PT Cola < CAT Coffee, Wine > CAT (ii) Surface sealant: Distilled water: < PT Coffee (2.15) and Cola < CAT Wine > CAT |
ΔE00 after 30 days (D) Temporis: (i) Polished: Distilled water: < PT Cola < CAT Coffee, Wine > CAT (ii) Surface sealant: Distilled water: < PT Cola < CAT Coffee, Wine > CAT |
Digital spectrophotometer (VITA Easyshade; Vita Zahnfabrik) |
|
Atria et al., 2020 [42] | N/A | Aging: Thermocycling: 6000 cycles at 5–50 °C |
PT and CAT Threshold values ## (A) Marche: 0.6 mm thickness: ΔE00 > PT 1.3 mm thickness: ΔE00 < PT (B) Protemp: 0.6 mm thickness: ΔE00 > PT 1.3 mm thickness: ΔE00 < PT |
(C) Telio CAD: 0.6 mm thickness: ΔE00 < PT 1.3 mm thickness: ΔE00 < PT |
(D) Raydent C&B: 0.6 mm thickness: ΔE00 > CAT 1.3 mm thickness: ΔE00 > CAT |
Spectrophotometer (VITA Easyshade; Vita Zahnfabrik) |
ΔE00: 3D-Printed hybrid composite > Conventional acryic and bisacrylic > CAD/CAM Milled PMMA |
N/A: Not Applicable; PT: perceptibility threshold; CAT: clinical acceptability threshold; ##: The ΔE00 evaluation is based on: PT set at ΔE00 ≤ 1.30 and the CAT set at ΔE00 ≤ 2.25 units.