Resilience Results (MJ/m3).

Author and Year Resilience for Conventional Resin Resilience for CAD/CAM Milled Resin Resilience for 3D-Printed Resin Exposure Agent/Aging Technique Testing Machine Used Authors Suggestions/Conclusions
Tas¸ın et al., 2022 [30] Median in (MJ/m3)
(A) Temdent Classic (PMMA):
Thermocycling:
(i) 0 cycles: 0.77
(ii) 2500 cycles: 0.64
(iii) 10,000 cycles: 0.53
(B) Protemp (Bis-Acryl):
Thermocycling:
(i) 0 cycles: 0.98
(ii) 2500 cycles: 0.81
(iii) 10,000 cycles: 0.72
Median in (MJ/m3)
(C) Duo Cad (PMMA):
Thermocycling:
(i) 0 cycles: 1.04
(ii) 2500 cycles: 0.93
(iii) 10,000 cycles: 0.85
Median in (MJ/m3)
(D) Temporis (composite resin):
Thermocycling:
(i) 0 cycles: 1.12
(ii) 2500 cycles: 1.03
(iii) 10,000 cycles: 0.74
Thermocycling Universal testing machine Resilience results after thermocycling for 10,000 cycles:
CAD/CAM milled PMMA > 3D-Printed composite resin > Conventional Bisacrylic > conventional PMMA