Skip to main content
. 2022 Jul 5;22(13):5049. doi: 10.3390/s22135049

Table 1.

Comparison of performance of proposed modified electrode in RhB detection.

Modified Electrode Detection Technique LOD (µM) Linear Range (µM) pH References
MnO2NRs-ERGO/GCE SDLSV 2.87 9.58–479;
479–9580
6 [31]
Cu@CS/GCE DPV 0.1 0.3–30 6.5 [32]
MWCNT/CPE DPV 0.02 0.1–15 3 [33]
MWCNT-PEI/GCE SDLSV 0.006 0.01–10 6.3 [34]
Nd-MOF/GCE DPV 0.0036 0.08–2.0;
2.0–4.0
6 [35]
GS/GCE DPV 0.0015 0.005–0.12 6.5 [36]
MWCNT-COOH/IL/PGE DPV 0.001 0.005–2.0;
2.0–60.0
5 [37]
Ag-3/ZnO/SPCE DPV 0.0008 0.06–12.11 7 This work

Abbreviations: MWCNT, multi-walled carbon nanotubes; IL, ionic liquid; PGE, pencil graphite electrode; Nd, neodymium; MOF, metal-organic framework; GCE, glassy carbon electrode; ERGO, electro-reduced graphene oxide; SDLSV, second-order derivative linear scan voltammetry; PEI, polyethylenimine; GS, graphene nanosheets; CPE, carbon paste electrode; CS, carbon sphere.