Skip to main content
. 2022 Jul 8;82:104127. doi: 10.1016/j.ebiom.2022.104127

Table 2.

nnU-Net Automatic Segmentation Performance. Accuracy represents percentage of overall percentage of correctly predicted areas in the overall image. Sensitivity corresponds to the percentage of nodules that were correctly predicted and annotated. Specificity refers to the percentage of healthy area that was correctly predicted and annotated.

CT Automatic Segmentation Performance
AUC Accuracy Sensitivity Specificity
Training Set 0.865 0.999 0.730 0.999
Validation Set 0.848 0.999 0.696 0.999
Test Set 0.828 0.999 0.657 0.999
PET Automatic Segmentation Performance
AUC Accuracy Sensitivity Specificity
Training Set 0.747 0.998 0.495 0.999
Validation Set 0.741 0.999 0.489 0.999
Test Set 0.755 0.999 0.510 0.999