Multiplexed immunofluorescence staining procedure

Verify Tumor with Surgical Pathologist (serial H&E)
Cy2 Cy3 Cy5 Cy7
Round 1 PRG2 CD31 CD141 CD103
Scan to Verify Quenched Slide (1)
Round 2 SMAα MPO LOX-1
Round 3 CD62L CD56 CD8 Granzyme B
Scan to Verify Quenched Slide (2)
Round 4 FOXP3 CD163 CD4
Round 5 MUC1 Tryptase EPCAM Ki67
Scan to Verify Quenched Slide (3)
Round 6 CCR3 CD3 CD19 CD11b
Round 7 GFAP IL10 CXCR3 CD45RA
Scan to Verify Quenched Slide (4)
Round 8 Vimentin PD1 FAP
Round 9 PDL1 iNOS
Post-MxIF H&E Staining
Verify Tumor/Stroma Areas with Surgical Pathologist