Skip to main content
. 2022 Mar;43(3):259–265. doi: 10.15537/smj.2022.43.3.20210782

Table 5.

- Distortion product otoacoustic emission results.

Frequencies Groups P-value
Hospitalized patients Outpatients Controls
Mean±SD Median (min-max) Mean±SD Median (min-max) Mean±SD Median (min-max)
1 kHz 8.54±3.42 8.15 (1.4-23.6) 9.15±4.62 8.25 (1.4-31.1) 9.48±4.42 10 (-1 - 18.4) 0.080*
2 kHz 12.41±5.92 10.9 (1.3-27.5) 11.54±5.24 10.3 (1.1-26.4) 14.61±5.09 14.65 (7.7-30.4) 0.009*
4 kHz 14.68±7.09 12.9 (2.2-34.6) 14.04±6.2 12.75 (5.1-28) 16.13±6.5 15.4 (4.7-27.2) 0.293*
6 kHz 12.68±5.45 11.75 (3.1-25.1) 11.45±5.45 10.6 (1.3-24.1) 10.98±4 10 (5.7-20.2) 0.298*

kHz: kilohertz, SD: standard deviation, Min: minimum, Max: maximum, *Kruskall-Wallis, a statistically significant difference (p<0.05)