Skip to main content
. 2022 Jul 1;7(27):23576–23590. doi: 10.1021/acsomega.2c02151

Table 5. Experimental Data of Heavy Metal Ion (Label Forms) Removal from Real Water Samples by the Obtained Mesoporous Adsorbentsa.

      added (μg/L) found (μg/L)
sample metal ion Cb, μg/L   TEOS/EDTA NaSi/EDTA/NH2 NaSi/NH2 TEOS/QAS
artesian drinking water Cd(II) 0.3 0 0.01 0.10 0.05 0.3
10 5.83 5.77 4.18 3.79
Cu(II) 6.0 0 0.8 0.9 1.8 5.7
10 2.8 3.7 6.5 9.4
Pb(II) 0.1 0 0.01 0.05 0.07 0.1
10 5.56 6.15 5.67 5.5
Mn(total) 3.0 0 1.8 2.0 2.9 1.2
10 2.8 3.0 4.9 6.2
Cr(total) 4.0 0 0.4 1.7 3.4 2.2
10 2.4 2.9 5.4 7.2
river water (Dnipro, Ukraine) Cd(II) 1.9 0 1.33 1.55 0.01 1.85
10 0.33 0.65 3.01 1.93
Cu(II) 5.0 0 1.1 1.1 0.61 4.92
10 1.9 1.1 3.61 8.56
Pb(II) 2.0 0 0.87 0.82 0.98 2.0
10 1.07 1.82 5.98 11.0
Mn(total) 13.0 0 5.1 6.6 7.9 7.4
10 10.1 9.5 11.8 16.4
Cr(total) 1.0 0 0.12 0.21 0.08 0.06
10 1.89 6.21 8.18 4.89
lake water (Virlytcya, Kyiv, Ukraine) Cd(II) 5.0 0 3.43 3.13 3.89 3.48
10 1.11 4.78 6.19 10.76
Cu(II) 9.0 0 2.1 1.3 1.93 8.3
10 2.34 4.24 5.5 12.8
Pb(II) 9.0 0 5.67 4.15 5.85 8.15
10 5.01 9.65 9.15 4.03
Mn(total) 18.0 0 8.6 7.9 7.9 11.9
10 2.9 5.78 9.0 10.76
Cr(total) 2.0 0 0.12 0.11 0.11 1.01
10 1.89 1.97 5.34 7.74
a

The analyzed water volume was 250 mL, pH 7.0–7.5, adsorbent dose 100 mg, time contact 12 h.

b

Determined by the ICP-OES method with the standard procedure.