Table 3.
Comparison with state-of-the-art methods on the COVID-X dataset [30].
Method | Data distribution | Accuracy % |
---|---|---|
COVID-Net (2020) [30] | 358 COVID-19, 5538 Pneumonia, 8066 Normal | 93.3 |
ECOVNet (2020) [52] | 589 COVID-19 , 6053 Pneumonia, 8851 Normal | 96.00 |
COVID-ResNet (2020) [16] | 68 COVID-19, 931 Bact. Pneumonia, 660 Viral Pneumonia, 1203 Normal | 96.23 |
COVID-CAPS (2020) [23] | Not specified | 98.3 |
COVIDiagnosis-Net (2020) [20] | 76 COVID-19, 4290 Pneumonia, 1583 Normal | 98.26 |
EDL-COVID (2021) [51] | 100 COVID-19, 594 Pneumonia, 885 Normal | 95 |
COVID-Net CT-2 S (2021) [32] | Not specified | 97.9 |
COVID-NET CT-2 L (2021) [32] | Not specified | 98.1 |
Blended ensembling | 568 COVID-19, 6052 Pneumonia, 8851 Normal | 94.55 |