Skip to main content
. 2022 Jul 15;78:104000. doi: 10.1016/j.bspc.2022.104000

Table 3.

Comparison with state-of-the-art methods on the COVID-X dataset [30].

Method Data distribution Accuracy %
COVID-Net (2020) [30] 358 COVID-19, 5538 Pneumonia, 8066 Normal 93.3
ECOVNet (2020) [52] 589 COVID-19 , 6053 Pneumonia, 8851 Normal 96.00
COVID-ResNet (2020) [16] 68 COVID-19, 931 Bact. Pneumonia, 660 Viral Pneumonia, 1203 Normal 96.23
COVID-CAPS (2020) [23] Not specified 98.3
COVIDiagnosis-Net (2020) [20] 76 COVID-19, 4290 Pneumonia, 1583 Normal 98.26
EDL-COVID (2021) [51] 100 COVID-19, 594 Pneumonia, 885 Normal 95
COVID-Net CT-2 S (2021) [32] Not specified 97.9
COVID-NET CT-2 L (2021) [32] Not specified 98.1

Blended ensembling 568 COVID-19, 6052 Pneumonia, 8851 Normal 94.55