Skip to main content
. 2001 May;67(5):2354–2359. doi: 10.1128/AEM.67.5.2354-2359.2001

TABLE 2.

Yield of DNA extracted from Dijon, Couhins, and Epoisses soils using the MoBio Laboratories kit, the Bio 101 kit, or the MS laboratory method

Soil sampling location Yield of DNA (μg/g of soil) witha:
MoBio Laboratories kit Bio 101 kit MS laboratory method
Dijon 0.19 ± 0.11 a 0.92 ± 0.46 ab 2.01 ± 1.07 b
Couhins 0.70 ± 0.23 ab 0.79 ± 0.36 ab 0.97 ± 0.10 b
Epoisses 0.47 ± 0.13 ab 1.01 ± 0.86 ab 2.52 ± 1.09 b
a

Values are means ± standard errors. (SE). Values followed by the same letter do not differ significantly (P < 0.05).