Basic restrictions for time-varying electric and magnetic fields for frequencies 10 MHz–10 GHz according to the International Commission on Non-Ionizing Radiation Protection (24)

Whole-body average SAR (W/kg) Localised SAR (W/kg)
Head and trunk Limbs
Occupational exposure 0.4 10 20
General public exposure 0.08 2 4