Skip to main content
. 2022 Jul 15;22:774. doi: 10.1186/s12885-022-09792-x

Table 6.

Diagnostic indicators of imaging modalities

Mammography A-MRIa P value**
False negative 6 0
True negative 183 78
False positive 8 21
True positive 1 5
Recall rate 9/198 (4.5%) 25/104 (25%)  < 0.00001
Biopsy rate 6/198 (3.0%) 19/104 (18.3%)  < 0.00001
CDR 1/198 (0.5%) 5/104 (4.8%) 0.0109
PPV2 (recommended) 1/6 (16.7%) 5/20 (25%) 0.59
PPV3 (performed) 1/6 (16.7%) 5/19 (26.3%) 0.557
Sensitivity (%, CI) 1/7 (14.2%, 0.36–57.8) 5/5 (100%) 0.004
Specificity (%, CI) 183/191 (95.8%, 91.9–98) 78/99 (78.8%) 0.00001

CI 95% confidence intervals, A-MRI Abbreviated breast MRI, CDR Cancer detection rate (per 1000 women), PPV2 Positive predictive value for biopsies recommended, PPV3 Positive predictive value for biopsies performed, CI Confidence interval

aincluding intra-mammary findings only,

**excluding extra-mammary findings, chi-square test for comparison between groups