Effect of different concentration levels on tested properties of conventionally and autoclave polymerized denture base material.

Property Groups Sum of Square Df Mean square F P
Group I Flexural strength Between groups 5655.29 3 1885.1 11.94 <0.0001
Within groups 4592.16 28 164.0
Total 10247.4 31
Modulus elasticity Between groups 660671.3 3 220223.7 5.394 0.004
Within groups 1469761.2 36 40826.7
Total 2130432.4 39
Impact strength Between groups 3.576 3 1.189 1.517 0.227
Within groups 28.206 36 0.783
Total 31.772 39
Hardness Between groups 44.5 3 14.852 1.926 0.143
Within groups 277.6 36 7.711
Total 322.1 39

Group II Flexural strength Between groups 1622.13 3 540.7 5.918 0.003
Within groups 2558.3 28 91.4
Total 4180.4 31
Modulus elasticity Between groups 256703.0 3 85567.7 1.074 0.373
Within groups 2869471.9 36 79707.5
Total 3126174.9 39
Impact strength Between groups 11.766 3 3.922 1.352 0.273
Within groups 104.47 36 2.902
Total 116.236 39
Hardness Between groups 59.453 3 19.818 4.822 0.006
Within groups 147.957 36 4.11
Total 207.410 39