Quality Control of MSCTC-0010, Suspension for Infusion

Analytical test Method Acceptance Criteria
Appearance Off-white, opaque, homogeneous suspension following mixing Visual, no clumps
Phenotype Flow Cytometry ≥ 80% CD73, CD90, CD105
≤ 2% CD45, CD34, CD11b, CD19, HLA DR
Cell Viability Flow Cytometry ≥ 80%
Potency by Immunosuppression Inhibition of PHA-induced proliferation of hPBMC by WJMSC ≥ 20%
Endotoxin Bacterial endotoxin USP <85> < 12.5 EU/ml
Mycoplasma Biochemical luminescence assay Absence of mycoplasma
Sterility Microbiological control of cellular product USP <71> Absence of micro organisms
Chromosomal Stability Karyotype Absence of chromosomal alterations