Skip to main content
. 2022 Jul 18;34:35. doi: 10.1186/s43019-022-00163-1

Table 3.

Risk factors for/causes of meniscal allograft extrusion [16, 102, 106, 109, 120]

1. Size mismatch between the affected joint surface and the allograft
2. Excessive peripheral suture tension
3. Nonanatomical placement of the allograft
4. Pre-existing osteophytes on the tibial plateau
5. Loss of fixation of the anterior and posterior horns
6. Non-repair of meniscotibial ligaments and popliteomeniscal fascicles
7. Bony inclination of the allograft
8. Position of the bone bridge
9. Fixation of the allograft