TABLE 7.
MD Codes™ | Injection area | Target layer | Tool | Delivery | Volume per site (ml)a |
---|---|---|---|---|---|
Ck1 | Zygomatic arch | Supraperiostialb | Needle | Bolus | 0.1+0.1+0.1 |
Ck4 | Lateral lower cheek/parotid area | Subcutaneous | Cannula | Fanning | 0.5 |
Jw1 | Mandible angle | Supraperiostealb | Needlec | Bolus | 0.5 |
Mandible angle | Subcutaneous | Cannula | Bolus | 0.5 | |
Jw2* | Pre‐auricular area | Subcutaneous | Cannula | Bolus | 0.5 |
Jw4 | Lower prejowl | Subcutaneous | Cannula | Bolus | 0.5 |
Jw5 | Lower anterior chin | Subcutaneous | Cannula | Bolus | 0.5 |
C1 | Labiomental angle | Subcutaneous | Cannula | Bolus | 0.5 |
C2 | Chin apex | Subcutaneous | Cannula | Bolus | 0.3 to 0.5 |
Chin apex | Supraperiostealb | Needlec | Bolus | 0.3 to 0.5 | |
C5* | Lateral lower chin | Supraperiostealb | Needlec | Bolus | 0.3 to 0.5 |
aRecommended volumes were determined based on the panel's clinical experience.
bDo not inject into the cartilage or bone but rather at the level of the cartilage or bone.
cAspiration is highly recommended when injecting with a needle at the level of the bone.
*Only in men.