Skip to main content
. 2021 Sep 22;77(12):5498–5508. doi: 10.1002/ps.6590

TABLE 1.

Summary of tests and parameters used in each experiment

Experiment Test Tested parameter Type of arena Sample size Variations of FS2
Exp 1 a. Amplitude of the playback Amplitude of the signal measured as substrate velocity (μm s−1) Bean plant 42 males

FS2 (0–8000 μm s−1);

Control – silence

b. Continuity of the playback Continuity of the signal (with or without silent breaks) Bean plant 20 males

FS2‐continuous – FS2 played in loop with no breaks;

FS2‐discontinuous – 11.5 s FS2‐2 playback with breaks of 11 s of silence;

Control – silence

c. Dominance of the harmonics Dominant frequency (Hz) Round arena 20 males

FS2‐76 – peak of frequency at the first harmonic (76 Hz);

FS2‐even – first and second harmonics equally important;

FS2‐152 – peak of frequency at the second harmonic (152 Hz);

d. Pulse repetition time PRT (s) Round arena 50 males

FS2‐fast – PRT at 1.0 s;

FS2‐standard – PRT at 1.5 s

Exp 2 a. One‐choice test Optimal Exp1 features (a, b, c, d) T arena 59 males FS2‐Best – FS2 continuous play, 76 Hz and 1 s PRT;
b. Simple two‐choice test Dominant frequency (Hz) T arena 38 males

FS2‐76 – peak of frequency at the first harmonic (76 Hz);

FS2‐152 – peak of frequency at the second harmonic (152 Hz);

c. Complex two‐choice test Dominant frequency (Hz) and PRT (s) T arena 80 males

FS2‐Best – FS2 with 100–150 μm s−1, continuous play, 76 Hz and fast PRT;

FS2‐Worst – FS2 with 100–150 μm s−1, continuous play, 152 Hz and standard PRT;

FS2‐Sub1 – FS2 with 100–150 μm s−1, continuous play, 76 Hz and standard PRT;

FS2‐Sub2 – FS2 with 100–150 μm s−1, continuous play, 152 Hz and fast PRT;