Description of included studies

Author/Year Study design Subjects n Mean age Implant system Design prosthesis Number of prosthesis Digital fabrication
Data acquisition Laboratory scanner CAD system CAM system Type of CAM Location of CAM Finalization of prosthesis
Di Fiore et al. (2018) prospective cohort study with a crossover design 10 na na fixed 10 Cerec Omnicam CEREC Biogeneric CEREC MC XL, Sirona

Subtractive

(monolithic crown)

point‐of‐care point‐of‐care
Joda and Bragger (2014) prospective cohort study 6 na Straumann Tissue Level fixed 3 iTero, Align Technology Straumann CARES Straumann CARES

subtractive

(monolithic crown)

implant manufacturer dental laboratory
3 subtractive (customized abutment, monolithic crown)
Joda and Bragger (2014) prospective cohort study with a crossover design 20 55.4y Straumann Tissue Level fixed 20 iTero, Align Technology Straumann CARES Straumann CARES subtractive (customized abutment, crown coping) implant manufacturer dental laboratory
Joda and Bragger (2016) Randomized controlled trial 20 55.4y Straumann Tissue Level fixed 10 iTero, Align Technology Straumann CARES Straumann CARES subtractive (monolithic crown) implant manufacturer dental laboratory
10 subtractive (customized abutment, model)
Mangano, Margiani, et al. (2019) retrospective cohort study 25 51.1 Exacone, Leone Implants fixed 40 CS 3,600, Carestream Dental Exocad DentalCAD, Exocad Roland DWX−50, Roland Easy Shape subtractive (abutment and monolithic crown dental laboratory dental technician
Mangano and Veronesi (2018) randomized controlled clinical trial 50 52.6 Exacone, Leone Implants fixed 25 CS 3,600, Carestream Dental Exocad DentalCAD, Exocad Roland DWX−50, Roland Easy Shape subtractive dental laboratory dental technician
Mangano, Mangano, et al. (2019) prospective cohort study 15 68.8 BTSafe, BTK removable 15 CS 3,600, Carestream Dental Exocad DentalCAD, Exocad 3500PD additive (prototype bar) dental laboratory
Roland DWX−51, Roland Easy Shape subtractive (PEEK bar) dental laboratory
Pan et al. (2019) prospective cohort study with a crossover design 40 45.1y Straumann Tissue Level and Bone Level fixed 40 Trios, 3Shape 3Shape Designer Zentotec Select Hybrid subtractive (monolithic crown) dental laboratory dental laboratory
40 conventional D2000, 3Shape
Zhang, Qiu, et al. (2019) Randomized controlled trial 33 46.8y CAMLOG SCREW‐LINE, Camlog Biotechnologies AG fixed 17 Cerec Omnicam CEREC CEREC MC XL Premium

subtractive

(monolithic crown)

point‐of‐care point‐of‐care (dentist, dental technician)
16 conventional Trios lab, 3Shape Trios lab, 3Shape centralized manufacture subtractive (crown coping) unknown