Skip to main content
. 2022 Jun 21;60(8):2307–2319. doi: 10.1007/s11517-022-02610-3

Table 1.

Number of total (NTOT) and coronary sinus (NCS) measurements used for calibration; conduction velocities CVf, CVs, CVn; mean relative error with standard deviation; distance D between measured and computational LEAS. In the first value for each box: Test I (consistency test). In the second value for each box: Test II (towards a clinically relevant test)

NTOT/NCS CVf(ms−1) CVs(ms−1) CVn(ms−1) Mean relative error (%) Std (%) D (cm)
P1 39/8 0.71/0.75 0.43/0.45 0.23/0.25 3.53/3.67 2.02/2.12 0.26/0.26
P2 32/7 0.59/0.64 0.37/0.40 0.17/0.19 4.92/5.18 2.65/2.73 0.32/0.31
P3 33/8 0.62/0.64 0.39/0.39 0.19/0.19 5.35/5.92 1.96/1.97 0.21/0.21
P4 32/7 0.61/0.62 0.38/0.39 0.19/0.19 5.62/6.21 2.19/2.35 0.16/0.16
P5 84/10 0.59/0.62 0.38/0.39 0.18/0.19 4.54/5.35 1.83/2.08 0.11/0.12
P6 25/6 0.61/0.63 0.39/0.39 0.19/0.19 5.24/5.44 2.28/2.42 0.41/0.41
P7 17/4 0.60/0.62 0.38/0.39 0.19/0.19 5.20/5.83 2.74/3.04 0.26/0.26
P8 20/7 0.55/0.57 0.35/0.36 0.15/0.16 7.76/8.44 2.5/2.96 0.09/0.09
P9 48/11 0.58/0.60 0.36/0.37 0.16/0.17 6.81/6.96 3.06/3.18 0.37/0.38
P10 86/10 0.59/0.62 0.37/0.39 0.19/0.18 3.25/4.07 1.53/1.87 0.08/0.09