. 2022 Jul 19;22:558. doi: 10.1186/s12909-022-03601-6

Table 1.

Hygienic venipuncture of medical students pre- and post-SARS-CoV-2 in Germany during 2019–2021 (N = 726)

All Before SARS-CoV-2 After SARS-CoV-2 P-value
Number of participants (N = 726) (N = 355) (N = 371)
 Winter semester 382 (52.6) 191 (53.8) 191 (48.5)
 Summer semester 344 (47.4) 164 (46.2) 180 (51.5)
Scores for other Stations
 Mean relative OSCE score 64.88 ± 8.18 62.53 ± 8.47 67.13 ± 7.22 < .001
 Mean relative score in venipuncture 72.25 ± 16.79 71.87 ± 15.85 74.36 ± 17.4 < .001
Doctor-patient communication
 The patient is not informed about the procedure 146 (20.1) 50 (14.1) 96 (25.9) < .001
 The patient is informed about the procedure 580 (79.9) 305 (85.9) 275 (74.1)
Preparation of the material
 More than one material or the sharp-safe is missing 211 (29.1) 85 (23.9) 126 (34) .691
 At least one material is missing 138 (19) 94 (26.5) 44 (11.9)
 Complete and correct preparation of the material 377 (51.9) 176 (49.6) 201 (54.2)
Hygienic hand disinfection and medical gloves prior to patient contact
 Neither hygienic hand disinfection nor medical gloves 16 (2.2) 13 (3.7) 3 (0.8) < .001
 Medical gloves without prior hand disinfection 61 (8.4) 45 (12.7) 16 (4.3)
 Hand disinfection and medical gloves 649 (89.4) 297 (83.7) 352 (94.9)
Tourniquet usage
 The tourniquet is not applied or disposed of correctly 67 (9.2) 51 (14.4) 16 (4.3) < .001
 The tourniquet is not applied, while the needle is pulled before disposing of the tourniquet 230 (31.7) 120 (33.8) 110 (29.6)
 The tourniquet is applied and disposed in the correct manner 429 (59.1) 184 (51.8) 245 (66)
Disinfection of the puncture site
 The puncture site is not disinfected, or it is palpated after the disinfection and prior to the venipuncture 86 (11.8) 59 (16.6) 27 (7.3) < .001
 The puncture site is correctly disinfected 640 (88.1) 296 (83.4) 344 (92.7)
Exposure time of the disinfectant
 30 seconds exposure time is not considered 27 (3.7) 18 (5.1) 9 (2.4) .06
 30 seconds exposure time is considered 699 (96.3) 337 (94.9) 362 (97.6)
Hygienic needle
 The needle is not sterile or is curved 112 (15.4) 52 (14.6) 60 (16.2) .57
 The needle is sterile and not curved 614 (84.5) 303 (85.4) 311 (83.9)
Correct venipuncture
 The vein is not punctured 171 (23.6) 81 (22.8) 90 (24.3) .041
 The vein is punctured the second time 245 (33.7) 105 (29.6) 140 (37.7)
 The vein is punctured the first time 310 (42.7) 169 (47.6) 141 (38)
Discarding the puncture needle
 The needle is not discarded correctly 339 (46.7) 174 (49) 165 (44.5) .177
 The needle is discarded immediately but not correctly 112 (15.4) 55 (15.5) 57 (15.4)
 The needle is discarded immediately and correctly 175 (37.9) 126 (35.5) 149 (40.2)
Hand disinfection after discarding the medical gloves
 Hands are not disinfected after discarding the medical gloves 445 (61.3) 286 (80.6) 149 (42.9) .000
 Hands are disinfected after discarding the medical gloves 281 (38.7) 69 (19.4) 212 (57.2)
Structure in the work process
 The work process is not structured 36 (5) 11 (3.1) 25 (6.7) .024
 The work process is partly structured 176 (24.2) 80 (22.5) 96 (25.9)
 The work process is structured 514 (70.8) 264 (74.4) 250 (67.4)

Counts are described by their frequency and percentage. Continuous variables are described by their mean and standard deviation

Statistic differences between pre- and post-SARS-CoV-2 was tested using the Mann-Whitney-U test