Skip to main content
. 2022 Jul 14;2(4):oeac044. doi: 10.1093/ehjopen/oeac044

Table 1.

Ongoing and completed randomized trials assessing atrial fibrillation screening

Study Number randomized Screening intervention Population
Studies cited in the current report
LOOP3 6004 Implanted monitor Age ≥70 with risk factors, Denmark
REHEARSE-AF4 1001 Hand-held ECG, BID for 1 year Age 65 + risk factors, UK/Wales
SCREEN-AF5 822 14-day ECG Patch, Twice Age ≥75 with hypertension, Canada/Germany
STROKESTOP6 28 768 Hand-held ECG, BID for 14 days Age 75 and 76, Sweden
Completed trials without published stroke outcomes and/or conducted in post-stroke population
Find-AF NCT01855035 398 10-day Holter, 0, 3, and 6 months Post-stroke, Germany
MonDAFIS NCT02204267 3470 7-day Holter, once Post-stroke, Germany
mSTOPS NCT02506244 2659 12-day ECG Patch, twice Age >75 or <75 with risk factors, USA
PerDIEM NCTT02428140 300 Implanted monitor Post-stroke, Canada
VITAL-AF NCT03515057 35 308 Hand-held ECG, once Age ≥65, USA
Ongoing trials
AMALFI ISRCTN15544176 5029 14-day ECG patch, once Age ≥65 with risk factors, UK
DANCAVAS ISRCTN12157806 79 000 3-lead ECG, once Men, age 60–74, Denmark
FIND-AF2 (high risk) NCT04371055 1040 Implanted monitor Post-stroke, Germany
FIND-AF2 (low risk) NCT04371055 4160 7-day Holter, once Post-stroke, Germany
GUARD-AF NCT04126486 11 931 14-day ECG Patch, once Age ≥70, USA
Heartline NCT04276441 150 000 ECG Watch Age ≥65, USA
SAFER-Internal Pilot ISRCTN16939438 14 082 Hand-held ECG, QID for 21 days Age ≥70, UK
SAFER-UK ISRCTN72104369 100 418 Hand-held ECG, QID for 21 days Age ≥70, UK
SAFER-AUS ISRCTN72104369 2100 Hand-held ECG, QID for 21 days Age ≥70, Australia
STROKESTOP II NCT02743416 28 712 Hand-held ECG, QID for 14 days Age 75/76 with elevated NT-ProBNP, Sweden