Table 1.
|
λabs,max [nm] |
λem,max [nm] |
ϵ [a] /×104 M−1 cm−1 |
Stokes‐shift[b] [nm] |
ΦD [c] [%] |
ΦBCN/ΦTet |
IBCN/ITet [d] |
---|---|---|---|---|---|---|---|
1 |
434/552 |
567 |
2.5/9.5 |
146 |
1.0 |
14.5 |
15.9 |
1.BCN |
406/552 |
566 |
2.2/9.3 |
14.5 |
|||
2 |
428/650 |
670 |
2.1/10.4 |
247 |
2.0 |
6.2 |
7.2 |
2.BCN |
403/650 |
669 |
2.3/10.4 |
12.4 |
|||
3 |
371/552 |
566 |
2.0/9.8 |
199 |
2.0 |
7.1 |
5.2 |
3.BCN |
367/552 |
566 |
2.0/9.7 |
14.2 |
|||
4 |
372/650 |
672 |
2.1/14.6 |
280 |
3.3 |
5.1 |
2.5 |
4.BCN |
370/650 |
670 |
2.0/14.3 |
16.8 |
[a] determined at λabs,max. [b] apparent Stokes‐shifts. [c] excited at the absorption maxima of the donors (relative to the respective standard (see Supporting Information)). [d] calculated at λem,max of the acceptor when excited at the λabs, max of the donor.