TABLE 7.
Experimental results of AD:MCI:HC classification on MRI slices (unit: %).
| Classification task | Model | Accuracy |
| AD:MCI:HC | VGG-16 | 84.38 |
| ResNet-18 | 86.79 | |
| ResNet-50 | 87.30 | |
| ResNet-50+Channel Shuffle | 87.30 | |
| CoT-ResNet-18 (ours) |
88.31 | |
| CCS-ResNet-50 (ours) |
88.61 |
Bolded numbers indicate the maximum value of the column.