Skip to main content
. 2022 Jun 26;9(7):278. doi: 10.3390/bioengineering9070278

Figure 4.

Figure 4

(A) Magnetic particle weight test in scaffolds of different groups. The final particle concentrations of the final scaffold products were compared with the initial weights included during the manufacture process. (B) Summary of the weight loss test of the testing scaffolds immersed in culture medium up to 4 weeks.