. 2022 Jul 11;11(14):4002. doi: 10.3390/jcm11144002

Table 1.

Comparison of digital and manual breast distances.

Distance Manual 3D Delta Range p R
Sn-N pre 180.4 ± 14.8 180.8 ± 14.7 −0.4 ± 1.6 −6.3 to 2.2 0.217 0.994
Sn-N post 189.3 ± 16.9 184.8 ± 18.1 0.5 ± 2.00 −4.9 to 5.7 0.120 0.991
N-M pre 64.5 ± 9.9 64.7 ± 9.6 −0.2 ± 1.4 −2.7 to 3.1 0.560 0.990
N-M post 91.1 ± 10.1 89.9 ± 11.2 1.2 ± 3.8 −11.5 to 8.9 0.090 0.939

Table 1 showing the manual and 3D measurements for the sternal notch to nipple distance (Sn-N) and nipple to inframammary fold distance (N-M) at the beginning (pre) and end (post) of surgery, their respective delta and range of deviation with p-value and correlation coefficient (R). All measurements are given in millimeters with their respective ± standard deviation.