Skip to main content
. 2017 Jul 8;26(2):572–582. doi: 10.1016/j.jfda.2017.06.002

Table 2.

Parameters linear range, regression equation, correlation coefficient (r2), retention time (tr), limit of quantification (LOQ) and limit of detection (LOD) for HCAA compounds.

Compound Linear range (ng/mL) Regression equation r tr (min) LOQ (ng/mL) LOD (ng/mL)
1 0.05–20 y = 0.0566x − 0.0007 0.9999 3.1 0.05 0.02
2 0.5–200 y = 0.0169x + 0.0290 0.9989 2.8 0.1 0.025
3 0.5–200 y = 0.0092x − 0.0097 0.9996 3.1 0.1 0.02
4 0.5–200 y = 0.0243x + 0.0136 0.9999 2.5 0.05 0.01
5 0.5–200 y = 0.0083x − 0.0287 0.9964 2.2 0.25 0.1
6 0.1–40 y = 0.0619x + 0.0038 0.9999 3.4 0.02 0.005
7 0.25–100 y = 0.0830x + 0.0113 0.9999 3.1 0.05 0.01
8 0.1–40 y = 0.0558x + 0.0011 0.9985 3.4 0.02 0.008
9 0.5–200 y = 0.0591x + 0.1257 0.9992 2.8 0.05 0.01
10 0.5–200 y = 0.0329x + 0.0324 0.9998 2.8 0.1 0.025
11 0.5–200 y = 0.0201x + 0.0128 0.9995 2.5 0.1 0.025
12 0.25–100 y = 0.0332x + 0.0089 0.9995 2.9 0.1 0.025
13 0.25–100 y = 0.0174x + 0.0020 0.9988 2.6 0.05 0.01
14 0.25–100 y = 0.0512x + 0.0038 0.9995 3.0 0.05 0.02
15 0.5–200 y = 0.0228x + 0.0007 0.9983 2.2 0.1 0.025
16 0.5–200 y = 0.0050x − 0.0114 0.9982 1.9 0.1 0.04
a

y means peak area ratio and x means concentration (ng/mL).