Skip to main content
. Author manuscript; available in PMC: 2022 Jul 27.
Published in final edited form as: Anal Biochem. 2020 Apr 13;601:113723. doi: 10.1016/j.ab.2020.113723

Table 3.

The linearity, LLOQ, and R2 of wogonoside, apigenin-7-O-glucuronide and baicalin in the bile and blood. The accuracies (%) at each concentrations of the standard curves were presented.

Analytes Linearity LLOQ (nM) R2

Bile Blood Bile Blood Bile Blood
Wogonoside 10.0–5000.0 1.56–4000.0 10.0 1.56 0.983 0.991
Apigenin-7-O-glucuronide 10.0–5000.0 1.56–4000.0 10.0 1.56 0.996 0.989
Baicalin 10.0–5000.0 1.56–4000.0 10.0 1.56 0.995 0.992
Conc.(nM) Accuracy in Blood (%) Conc.(nM) Accuracy in Bile (%)


Wogonoside Apigenin-O-7-glucuronide Baicalin Wogonoside Apigenin-O-7-glucuronide Baicalin
1.56 92.7 98.2 112 10 90.8 86.9 97.9
3.12 111 135 81.1 20 110 119 86.7
6.25 112 118 90.7 39 109 108 124
12.5 86.1 93 102 78 111 98.9 100
25 112 111 94.3 156 113 91 103
50 88.1 77.2 109 312 108 118 115
100 98.7 91.4 102 625 96.7 108 100
200 101 100 110 1250 98.1 107 96.9
400 98 85.1 100 2500 85.2 95.5 86.8
5000 79.5 80.9 86.6